The short version
Cyber insurers now ask manufacturers about the plant network, as well as the office. The specialist insurer Beazley publishes an OT supplemental application that asks about PLCs, HMIs and SCADA by name. Brokers report the same focus. In October 2025, Business Insurance quoted John Farley of Gallagher: insurers look at whether IT and operational technology are kept apart, and how well each is managed.
The questions fall into six areas: MFA on remote access, separation of OT from IT and the internet, an asset inventory, end-of-life machines, backups and a recovery plan. A good answer is a "yes" backed by a document you can attach. That means a network diagram, a list of vendors with access, session logs and a backup test record.
This post lists the questions, what a good answer looks like, and what to have ready before your renewal.
Why insurers ask about the plant floor
Ransomware that reaches production turns into a business interruption claim. Marsh made the link in its April 2022 report, Cyber resilience: Twelve key controls. It says encrypted systems usually stop a business from operating, which causes large interruption losses. It also says some controls "have now become a minimum requirement of insurers."
The same report names OT directly. It notes that end-of-life systems are common where they "control operational technology (OT)," because those systems are hard and costly to upgrade.
Our post on ransomware targeting manufacturing in 2026 covers the attack path. It usually starts in IT and crosses into the plant through flat networks and vendor access. Underwriters ask about exactly those paths.
The questions and how to answer them
Most of the questions below come from Beazley's public OT supplemental application. Some of its questions apply only to applicants above $500 million in revenue. Your carrier's form will differ in wording, but the topics repeat across the market.
| Insurer question | What a good answer looks like | Evidence to attach |
|---|---|---|
| Is OT segmented from IT? How? | Yes. A firewall or DMZ sits between the office and the machines, and only listed flows pass. | Network diagram showing the zones and the boundary device |
| Is OT segmented from the internet? Any OT assets exposed? | Yes. No machine is reachable from the internet. | Diagram, plus an external scan or firewall rule export |
| Do employees have remote access to OT? Is MFA enforced? Separate accounts? | Yes, MFA on every session, one named account per person. | MFA policy and a sample of session logs by user |
| Do third parties have remote access to OT? Is MFA enforced? | Yes, MFA for every vendor, access limited to the machines they service. | List of vendors with access, per machine, and their session logs |
| Is remote access logged, time limited and closed after each session? | Yes, each session is logged and ends when the work ends. | Log extract showing start, end, user and target |
| Do you keep a complete, current OT asset inventory? | Yes, updated from what is on the network. | Asset list with model, firmware and location |
| Do you run end-of-life devices? What protects them? | Yes, listed, with access restricted and no internet path. | EOL list and the access rules for each device |
| Do you back up OT, offline or on a separate network? Tested? | Monthly or on change, one copy offline, a restore tested this year. | Backup schedule and the last restore test record |
| Do you have a recovery plan for an OT cyber incident, including ransomware? | Yes, updated in the last two years and exercised in a tabletop. | The plan and the tabletop date and notes |
Remote access and MFA, for staff and vendors
MFA on remote access is the first control most forms check. Marsh lists "MFA for remote access and privileged or administrator access" first among its twelve controls. It advises MFA on all remote logins, including VPN and RDP.
Beazley asks the question twice: once for employees and once for third parties. It also asks whether employees share accounts. In a plant, the weak point is usually the vendor. Integrators and machine builders often connect through a shared login, a permanent VPN or a remote desktop tool installed on an HMI.
A good answer covers every path into the machines. List each vendor, the machines they reach and how they log in. If one path skips MFA, fix it before you sign the form. Our guide to MFA for remote access covers VPN, RDP and cloud portals. For the plant side, see secure OT remote access.
Separating OT from IT and the internet
Underwriters want a boundary between the office network and the machines. Beazley's form asks how the separation is built. The listed options are firewalls, unidirectional gateways, VLANs and DMZs.
A diagram is the evidence. It should show the office zone, the machine zone and the device between them. In the Purdue model that device sits at Level 3.5, the industrial DMZ. Show which flows cross it, such as a program download or a production report.
The internet question is separate. The form asks whether any OT asset is exposed directly to the internet. A remote desktop port opened on a router for a vendor years ago counts. An external scan of your public IP addresses answers it.
Asset inventory and end-of-life machines
You cannot answer the end-of-life question without an inventory. Beazley asks for a "complete and up to date centrally held inventory of your OT assets." It then asks whether any device is end of life or no longer receives security patches.
Most plants answer yes to the second question. A Windows 7 HMI or a controller with no firmware updates is normal. The form leaves space to describe what you do instead of patching. Marsh describes the accepted compensating controls: restrict access to the system, keep it off the internet and isolate it from other connected systems.
Your answer should name the machines and the control in front of each one. "Only the machine builder can reach it, with MFA, and every session is logged" is a specific answer.
Backups, recovery plans and business interruption
Insurers ask whether you could restart the plant without paying a ransom. Marsh says one copy of the backup should be offline and unconnected from the network, and that backups should be tested regularly. Beazley asks whether OT backups run at least monthly or after significant process changes. It also asks whether backups are offline or on a separate network, and whether you tested a recovery in the past year.
For a plant, backups mean PLC programs, HMI projects, recipes and drive parameters, as well as servers. The record of your last restore test is the evidence.
The recovery plan questions follow. Beazley asks for a business continuity plan updated in the last two years that covers OT recovery from ransomware. It asks whether the plant can keep running if IT is shut down. For larger manufacturers, it asks how many days of stock you hold and whether another plant could cover the shortfall. Those answers size your business interruption exposure.
Prepare the continuity answer before the form arrives. Keep one copy of the machine backups offline, away from the plant network. Write down how each line runs in manual mode, and who decides to switch. Plan a separate way to reach the plant, such as a spare laptop and a cellular link, for when the office network is shut down. Test it once in a tabletop exercise.
What the policy may leave out
Read the exclusions and sublimits together with the questionnaire. Three points matter for a manufacturer.
- Physical damage: traditional cyber policies typically exclude bodily injury and property damage, per AXA XL in Business Insurance (October 2025). Property policies may carry cyber exclusions or sublimits.
- State-backed attacks: Lloyd's Market Bulletin Y5381 requires standalone cyber policies written at Lloyd's to carry a state-backed cyber-attack exclusion, from 31 March 2023.
- Supplier outages: Munich Re advises that contingent business interruption should not be covered as standard, and should be limited to direct suppliers with sublimits.
Ask your broker which of these apply to your policy, and at what limits.
Where Access Gate fits
Trout Access Gate IDMZ produces evidence for four topics in the table. It sits at Purdue Level 3.5, between the office network and the machines. Every remote and vendor session to a machine passes through it.
It asks each person for MFA, with a TOTP code, before any traffic reaches a machine. It gives a vendor a time-limited session to the machines they service. It logs every session with the named user, the time, the source and the target. It keeps an asset list from what it sees on the network. Those outputs map to the remote access, segmentation, inventory and end-of-life rows of the table.
Access Gate is installed in a day per site. You connect it to your existing firewall or router and add one rule that forwards the machine traffic to it. Nothing changes on the machines. Access Gate IDMZ starts at $5,745 per site per year.
Access Gate does not set your premium or guarantee coverage. The carrier decides both. Access Gate gives you session logs and an asset list to attach to your answers.
What to prepare before your renewal
Collect the evidence before the questionnaire arrives. Give one person the job, and keep the documents in one folder.
- A network diagram with the office zone, the machine zone and the boundary between them.
- A list of every vendor with remote access, the machines they reach and how they authenticate.
- An asset list with end-of-life machines flagged, and the control in front of each one.
- The last OT backup restore test and the date of the last tabletop exercise.
Send the folder to your broker with the application. Use the free-text section of the form to describe your compensating controls.