TroutTrout
Back to Blog
Industrial DMZOT SecurityManufacturingCost Analysis

Industrial DMZ cost for one plant: the two-firewall build compared with one appliance

Trout TeamLast updated: 9 min read

A classic industrial DMZ for one plant is a network project with five cost lines: firewalls, switches, servers, integrator design work and the people who maintain the rules. Vendors and integrators quote it per project, so there is no public list price for the whole build. Trout Access Gate IDMZ does the same Level 3.5 jobs in one appliance beside your existing IT firewall. It costs $5,745 per site per year (Small) or $11,240 per site per year (Large), and it is up in a day.

This post is for the IT or infrastructure lead, or the plant director with the budget, who has been told the plant needs an IDMZ. It lists what each approach costs in money, time and staff. For the definition of an industrial DMZ and how it compares with plain firewall segmentation, see the Access Gate IDMZ product page and industrial DMZ, firewall segmentation or CMMC enclave.

What the guidance asks the industrial DMZ to do

The guidance asks for a zone where no traffic passes directly from IT to the control network. NIST SP 800-82 Rev. 3, the Guide to OT Security, lists "employing a DMZ network architecture (e.g., prevent direct traffic between the corporate and OT networks)" among its recommended practices. It also says the services in the DMZ "must be monitored and protected" because the DMZ connects to outside networks.

CISA gives the same advice. Advisory AA25-212A, published with the US Coast Guard in July 2025, recommends a DMZ between IT and OT and asks operators to "deploy bastion hosts in a DMZ."

In practice, a plant DMZ carries a short list of flows:

  • Historian data going up to the business systems
  • Patches and antivirus updates going down to the plant
  • Remote sessions from engineers and machine vendors
  • File transfers, such as programs and reports

Every one of those flows ends at a service in the DMZ. A new connection then starts on the other side. That is what both builds below have to deliver.

The classic build follows the Rockwell and Cisco CPwE design

The classic build uses two firewalls, or one three-legged firewall, with a set of servers between them. The Converged Plantwide Ethernet (CPwE) architecture from Rockwell Automation and Cisco is the reference most integrators follow. Its IDMZ guidance places plant firewalls in an active and standby pair. The DMZ then holds physical or virtual servers for patch management, antivirus, application mirrors, a reverse proxy and a remote desktop gateway.

For one mid-size plant, that design turns into this bill of materials:

ItemWhat it does in the DMZHow it is priced
Firewall pair or three-legged firewallSeparates IT, DMZ and plant zonesHardware plus yearly support and threat subscriptions, quoted by the reseller
DMZ switchingConnects the DMZ servers to both firewallsHardware plus support
Virtualization hostRuns the DMZ serversHardware plus hypervisor licensing
Remote desktop gateway and jump hostEnds engineer and vendor sessionsWindows Server licenses plus Remote Desktop CALs
Patch and antivirus relayStages updates for the plantWindows Server license plus the patch and AV products
Historian mirrorCopies plant data for business usersHistorian vendor license for the mirror
Directory, MFA and log collectionIdentifies users and keeps the audit trailDirectory and MFA licensing, a log server
Integrator design and installationZone design, rules, server builds, cutoverIntegrator quote, per project
Rule and server maintenanceFirewall rules, Windows patching, certificate renewalsYour staff time, every year

Only a few of these lines have public prices. Microsoft lists Windows Server 2025 Standard at $1,176 per 16-core license, before the client access licenses each user needs. A DMZ with four Windows servers on separate licenses starts at 4 x $1,176 = $4,704 in server licenses alone. Firewalls, switches, historian mirrors and integrator work are quoted per project. We do not put a number on those lines, because none is published.

The classic build also costs time and people

The classic build also needs design, cutover and maintenance work from skilled staff. Designing one takes skills in firewalls, access lists, virtual servers, system hardening and application security. Running it takes the same skills every week, for every rule change and every server patch.

The time goes into three places. The design phase defines zones, flows and the new IP addressing for the plant side. The cutover needs change windows, because machines move behind new firewalls and often get new addresses. Then the rules, the Windows servers and the certificates need care every month.

The US Bureau of Labor Statistics puts the median salary of a network and computer systems administrator at $99,130 a year (May 2025). Each tenth of one administrator's year spent on the DMZ is $9,913 in median salary. That is before benefits, and before any integrator support contract.

The appliance approach puts the Level 3.5 jobs in one box

Trout Access Gate IDMZ does the industrial DMZ jobs in one appliance. It filters every flow between zones. It acts as an authenticating proxy, so each person signs in before a session reaches a machine. It is the bastion for engineer and vendor remote access. It asks for MFA and writes one audit log with the user, the time, the source and the target.

The same appliance can also host the services an IDMZ usually runs on separate servers: remote access, protocol gateways, DNS and time, a historian and an update server.

Access Gate works beside your existing IT firewall. Your Fortinet, Cisco Meraki or Palo Alto firewall stays the perimeter. Access Gate handles the plant side: per-machine access, vendor sessions and audit evidence.

One route on your existing router or firewall sends traffic through it. Nothing changes on the machines. They keep their IP addresses, and nothing is installed on them. Removing that route is the rollback. On a Meraki MX, the change is one Protection LAN VLAN and two routes.

Deployment is up in a day per site. At Thales, it took 4 hours per site.

Side by side for one plant

Classic two-firewall IDMZAccess Gate IDMZ (Trout)
HardwareFirewall pair, DMZ switches, virtualization hostOne appliance per site
Servers to runFour or more (jump host, patch, AV, historian mirror, logging)Services hosted on the appliance
PriceQuoted per project, plus yearly support$5,745 (Small) or $11,240 (Large) per site per year
Design workIntegrator project: zones, flows, new addressingYour team chooses which flows and machines to allow
Change to the networkNew VLANs, new firewalls, often new IP addressesOne route on the existing router or firewall
Time to first protected linePlanned as a network project with change windowsUp in a day per site
RollbackUndo the cutover in a change windowRemove the route
Audit trailSpread across firewalls, VPN and jump serversOne log per session: user, time, source, target
Skills to maintainFirewall, Windows Server, hardening, applicationsYour IT team, on one appliance

The Small model runs on Essential hardware. The Large model runs on Performance hardware. Both prices are list prices billed yearly, and they include hardware, software, updates and support. A virtual option is also available, priced through sales. See pricing for what each size includes.

For a sense of scale: the Small price is $5,745 / $99,130 = 5.8% of the median administrator salary above. That compares the appliance with staff time alone, before any firewall or server cost on the classic side.

When the classic two-firewall build is the right choice

The classic build is the right choice in three cases.

The first case is a very large site. A refinery or a multi-building campus with dozens of lines and many data flows may need the capacity and the redundancy of a dedicated firewall pair and server farm.

The second case is a company with an existing firewall team. If a central team already runs CPwE-style DMZs at other plants, with templates and on-call staff, the marginal cost of one more is lower. Consistency across plants also has value.

The third case is a data diode requirement. Some sites must send data one way only, by hardware. NIST SP 800-82 Rev. 3 lists unidirectional gateways as an option for separating corporate and OT networks. An appliance like Access Gate does not replace a data diode.

For everyone else, the question is how much of the classic build the plant will actually staff and maintain. The industrial DMZ design patterns resource shows the common layouts, and the TCO comparison of appliance and cloud OT security covers the hidden costs on other approaches.

How to scope the budget for your plant

Start with the flows, then price the boxes. The flows decide the size of either build.

  • List every flow that crosses between IT and the plant today, with its source and target.
  • Count the people and vendors who need remote access, and to which machines.
  • Ask your integrator for a line-item quote that includes three years of support and maintenance.
  • Compare that quote with the per-site price of Access Gate IDMZ over the same three years.

At list price, three years of the Small model is 3 x $5,745 = $17,235 per site, and three years of the Large model is 3 x $11,240 = $33,720 per site. Put those figures next to the integrator quote, and next to the staff time your team will spend on rules and servers. That comparison gives the plant director a number to approve.

FAQ

Frequently Asked Questions

How much does an industrial DMZ cost for one plant?
A classic build has five cost lines: two firewalls or a three-legged firewall with support contracts, DMZ switches, four or more servers with their licenses, integrator design and installation, and staff time to maintain the rules. Vendors and integrators quote these per project, so the total depends on the plant. Trout Access Gate IDMZ does the same Level 3.5 jobs in one appliance for $5,745 per site per year (Small) or $11,240 per site per year (Large).
Is an industrial DMZ still necessary?
Yes, if anything on the IT network or outside the plant needs to reach the control network. NIST SP 800-82 Rev. 3 recommends a DMZ that prevents direct traffic between the corporate and OT networks, and CISA advisory AA25-212A recommends a DMZ between IT and OT with bastion hosts in it. The DMZ is where historian data, patches and remote sessions are checked before they reach the machines.
Is an industrial DMZ the same as a firewall?
No. A firewall filters traffic by address and port. An industrial DMZ is a zone between IT and OT where every flow ends at a service, such as a jump host, a historian mirror or a patch server, and a new connection starts on the other side. A classic DMZ uses firewalls to build that zone. Trout Access Gate IDMZ provides the zone filtering and the services in one appliance beside your existing firewall.
How long does it take to deploy an industrial DMZ?
A classic two-firewall build needs design work, new VLANs, new IP addresses on the plant side and change windows, so it is planned as a network project. Trout Access Gate IDMZ is up in a day per site. One route on your existing router or firewall sends traffic through it, and removing that route is the rollback.
When is the classic two-firewall IDMZ the better choice?
It fits very large sites with many lines and many data flows, companies that already run a dedicated firewall team, and sites that require a data diode for one-way transfer. In those cases the firewall pair and server farm are already staffed, and the extra cost buys capacity and a hardware one-way path that an appliance does not replace.

Other Articles

Cyber InsuranceManufacturing

Cyber insurance for manufacturers: the OT questions underwriters ask and how to answer them

Cyber insurers now ask manufacturers about the plant network: MFA on employee and vendor remote access, separation of OT from IT and the internet, an OT asset inventory, end-of-life machines, offline backups and a tested recovery plan. Answer each one with a document you can attach, such as a network diagram, a vendor access list, session logs or a backup test record.

Industrial DMZOT Security

How to get historian, MES and ERP data through an industrial DMZ

Put a replica or a broker in a Level 3.5 industrial DMZ, let the OT side push data out to it, and let ERP, MES, BI and cloud tools read only from the DMZ. No IT system opens a connection to Level 2 or below, and every human or vendor session to the plant goes through MFA and an audit log in the DMZ.

Incident responseOT Security

How to Build an OT Incident Response Plan for a Plant

An OT incident response plan decides five things before an attack: who can cut the link between IT and OT, which lines can run without IT, how engineers reach the plant when the corporate network is down, which evidence to keep, and how to check the machines before restarting. Write those decisions down, name the people, and test them twice a year.