A classic industrial DMZ for one plant is a network project with five cost lines: firewalls, switches, servers, integrator design work and the people who maintain the rules. Vendors and integrators quote it per project, so there is no public list price for the whole build. Trout Access Gate IDMZ does the same Level 3.5 jobs in one appliance beside your existing IT firewall. It costs $5,745 per site per year (Small) or $11,240 per site per year (Large), and it is up in a day.
This post is for the IT or infrastructure lead, or the plant director with the budget, who has been told the plant needs an IDMZ. It lists what each approach costs in money, time and staff. For the definition of an industrial DMZ and how it compares with plain firewall segmentation, see the Access Gate IDMZ product page and industrial DMZ, firewall segmentation or CMMC enclave.
What the guidance asks the industrial DMZ to do
The guidance asks for a zone where no traffic passes directly from IT to the control network. NIST SP 800-82 Rev. 3, the Guide to OT Security, lists "employing a DMZ network architecture (e.g., prevent direct traffic between the corporate and OT networks)" among its recommended practices. It also says the services in the DMZ "must be monitored and protected" because the DMZ connects to outside networks.
CISA gives the same advice. Advisory AA25-212A, published with the US Coast Guard in July 2025, recommends a DMZ between IT and OT and asks operators to "deploy bastion hosts in a DMZ."
In practice, a plant DMZ carries a short list of flows:
- Historian data going up to the business systems
- Patches and antivirus updates going down to the plant
- Remote sessions from engineers and machine vendors
- File transfers, such as programs and reports
Every one of those flows ends at a service in the DMZ. A new connection then starts on the other side. That is what both builds below have to deliver.
The classic build follows the Rockwell and Cisco CPwE design
The classic build uses two firewalls, or one three-legged firewall, with a set of servers between them. The Converged Plantwide Ethernet (CPwE) architecture from Rockwell Automation and Cisco is the reference most integrators follow. Its IDMZ guidance places plant firewalls in an active and standby pair. The DMZ then holds physical or virtual servers for patch management, antivirus, application mirrors, a reverse proxy and a remote desktop gateway.
For one mid-size plant, that design turns into this bill of materials:
| Item | What it does in the DMZ | How it is priced |
|---|---|---|
| Firewall pair or three-legged firewall | Separates IT, DMZ and plant zones | Hardware plus yearly support and threat subscriptions, quoted by the reseller |
| DMZ switching | Connects the DMZ servers to both firewalls | Hardware plus support |
| Virtualization host | Runs the DMZ servers | Hardware plus hypervisor licensing |
| Remote desktop gateway and jump host | Ends engineer and vendor sessions | Windows Server licenses plus Remote Desktop CALs |
| Patch and antivirus relay | Stages updates for the plant | Windows Server license plus the patch and AV products |
| Historian mirror | Copies plant data for business users | Historian vendor license for the mirror |
| Directory, MFA and log collection | Identifies users and keeps the audit trail | Directory and MFA licensing, a log server |
| Integrator design and installation | Zone design, rules, server builds, cutover | Integrator quote, per project |
| Rule and server maintenance | Firewall rules, Windows patching, certificate renewals | Your staff time, every year |
Only a few of these lines have public prices. Microsoft lists Windows Server 2025 Standard at $1,176 per 16-core license, before the client access licenses each user needs. A DMZ with four Windows servers on separate licenses starts at 4 x $1,176 = $4,704 in server licenses alone. Firewalls, switches, historian mirrors and integrator work are quoted per project. We do not put a number on those lines, because none is published.
The classic build also costs time and people
The classic build also needs design, cutover and maintenance work from skilled staff. Designing one takes skills in firewalls, access lists, virtual servers, system hardening and application security. Running it takes the same skills every week, for every rule change and every server patch.
The time goes into three places. The design phase defines zones, flows and the new IP addressing for the plant side. The cutover needs change windows, because machines move behind new firewalls and often get new addresses. Then the rules, the Windows servers and the certificates need care every month.
The US Bureau of Labor Statistics puts the median salary of a network and computer systems administrator at $99,130 a year (May 2025). Each tenth of one administrator's year spent on the DMZ is $9,913 in median salary. That is before benefits, and before any integrator support contract.
The appliance approach puts the Level 3.5 jobs in one box
Trout Access Gate IDMZ does the industrial DMZ jobs in one appliance. It filters every flow between zones. It acts as an authenticating proxy, so each person signs in before a session reaches a machine. It is the bastion for engineer and vendor remote access. It asks for MFA and writes one audit log with the user, the time, the source and the target.
The same appliance can also host the services an IDMZ usually runs on separate servers: remote access, protocol gateways, DNS and time, a historian and an update server.
Access Gate works beside your existing IT firewall. Your Fortinet, Cisco Meraki or Palo Alto firewall stays the perimeter. Access Gate handles the plant side: per-machine access, vendor sessions and audit evidence.
One route on your existing router or firewall sends traffic through it. Nothing changes on the machines. They keep their IP addresses, and nothing is installed on them. Removing that route is the rollback. On a Meraki MX, the change is one Protection LAN VLAN and two routes.
Deployment is up in a day per site. At Thales, it took 4 hours per site.
Side by side for one plant
| Classic two-firewall IDMZ | Access Gate IDMZ (Trout) | |
|---|---|---|
| Hardware | Firewall pair, DMZ switches, virtualization host | One appliance per site |
| Servers to run | Four or more (jump host, patch, AV, historian mirror, logging) | Services hosted on the appliance |
| Price | Quoted per project, plus yearly support | $5,745 (Small) or $11,240 (Large) per site per year |
| Design work | Integrator project: zones, flows, new addressing | Your team chooses which flows and machines to allow |
| Change to the network | New VLANs, new firewalls, often new IP addresses | One route on the existing router or firewall |
| Time to first protected line | Planned as a network project with change windows | Up in a day per site |
| Rollback | Undo the cutover in a change window | Remove the route |
| Audit trail | Spread across firewalls, VPN and jump servers | One log per session: user, time, source, target |
| Skills to maintain | Firewall, Windows Server, hardening, applications | Your IT team, on one appliance |
The Small model runs on Essential hardware. The Large model runs on Performance hardware. Both prices are list prices billed yearly, and they include hardware, software, updates and support. A virtual option is also available, priced through sales. See pricing for what each size includes.
For a sense of scale: the Small price is $5,745 / $99,130 = 5.8% of the median administrator salary above. That compares the appliance with staff time alone, before any firewall or server cost on the classic side.
When the classic two-firewall build is the right choice
The classic build is the right choice in three cases.
The first case is a very large site. A refinery or a multi-building campus with dozens of lines and many data flows may need the capacity and the redundancy of a dedicated firewall pair and server farm.
The second case is a company with an existing firewall team. If a central team already runs CPwE-style DMZs at other plants, with templates and on-call staff, the marginal cost of one more is lower. Consistency across plants also has value.
The third case is a data diode requirement. Some sites must send data one way only, by hardware. NIST SP 800-82 Rev. 3 lists unidirectional gateways as an option for separating corporate and OT networks. An appliance like Access Gate does not replace a data diode.
For everyone else, the question is how much of the classic build the plant will actually staff and maintain. The industrial DMZ design patterns resource shows the common layouts, and the TCO comparison of appliance and cloud OT security covers the hidden costs on other approaches.
How to scope the budget for your plant
Start with the flows, then price the boxes. The flows decide the size of either build.
- List every flow that crosses between IT and the plant today, with its source and target.
- Count the people and vendors who need remote access, and to which machines.
- Ask your integrator for a line-item quote that includes three years of support and maintenance.
- Compare that quote with the per-site price of Access Gate IDMZ over the same three years.
At list price, three years of the Small model is 3 x $5,745 = $17,235 per site, and three years of the Large model is 3 x $11,240 = $33,720 per site. Put those figures next to the integrator quote, and next to the staff time your team will spend on rules and servers. That comparison gives the plant director a number to approve.